Architectural Glass: Hurricane-Resistant/StormGlass™

Standards / Requirements

  StormGlass™ Meets or Exceeds the Following Standards

  UL 972

Burglary-Resistant Glazing

  ASTM F1233 Class 1

Standard Test Method for Security Glazing

  CPSC 16CFR 1201 Cat II

Safety Glazing

  ANSI Z 97.1

Safety Glazing

  ASTM E1886

Impact and Cyclic Pressures

  Miami Dade Protocols

PA 201, PA 202, PA 203

  Miami Dade NOA #08-1118.07

Expiration Date December 11, 2013


  Product Configuration

Outboard
Lite



Interlayer


Inboard
Lite



Minimum
Thickness



Average
Thickness



Maximum
Thickness



Weight
lbs/sq ft


1/8" (3mm) 0.075" (1.90mm) 1/8" (3mm) .301 .325 .347 3.8
3/16" (5mm) 0.075" (1.90mm) 3/16" (5mm) .431 .445 .477 5.3
1/4" (6mm) 0.075" (1.90mm) 1/4" (6mm) .509 .521 .567 6.8

*Notes: For hurricane-resistant glazing applications StormGlass™ should be used as a component in a tested system. The actual glass thickness and the maximum size is determined by this system testing. When insulating glass is required StormGlass™ should preferably be used as the inboard lite of the unit.